WebQuick Response Extra-Large Orifice Pendent Sprinkler VK377 Maximum 175 PSI (12 Bar) WWP Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm cULus4,5 NYC VdS LPCB 08337 VK377 Pendent 3/4” 20 mm 11.2 161.3 2-5/16 58.7 … WebK factor 5.6 Remember: you need 1/2 in. Sprinkler Orifice. Number of sprinkler = Ap/As 47 sprinkler. Flow rate per sprinkler(Qs)= D * As 30 gpm . P residual = 28.699 psi. Pipe material Black steel (wet systems including deluge) ... (in) Nominal Pipe Size Thickness (in) External Internal. 6 in. 8 in. 10 in. 12 in. 1/2 in. 0.84 0.62 0.11 ...

Fire Sprinkler Head Types Spectrum Fire Protection Blog

http://www.tycobuilding.com/en/emea/DocumentandMedia1/Brochure/Sprinklers/TFP802_09_2011.pdf WebThey are standard orifice fire sprinklers for installation in fire sprinkler systems designed in accordance with standard installation rules, e.g. EN12845 or the requirements of the … kids birthday party raleigh nc https://glynnisbaby.com

Pendent Sprinkler TY2236 Tyco White 4.9k 155F Residential

Websoftware uses the following guide: ANSI/ISA-75,01.01-2002 - Flow Equations for Sizing Control Valves. For predicting all physical properties of water we use the IFC-97 formulations developed by the International Association for the Properties of Water and Steam. For calculation of liquid or gas flow pressure losses across orifice plates we use the WebSprinkler Type Nominal Orifice Thread Size “K” Factor Max. Working Pressure Sprinkler Identification Number (SIN) Sprinkler Height Approvals US Metric Pendent ½” (15mm) ½” NPT (R ½) 5.6 80 250 PSI (cULus) 175 psi (FM) RA1414 2.25” 1,2 Upright ½” (15mm) ½” NPT (R ½) 5.6 80 RA3195 2.25” 1,2 Model F156 and F1FR56 Intermediate ... Web11) Every five years, all sprinklers should be visually examined and representative samples removed and tested to the requirements of the authority and/or insurer. 12) Approved with polished chrome and white polyester finishes. 13) This ESFR sprinkler has a k-factor of 362.9 l.min-1.bar -/2 (US k-factor of 25.2 gal.min-1.psi-/2). is michael lockwood a good father

Protection and Installation Device for Fire Protection Sprinklers ...

Category:Automatic Fire Sprinkler Systems Information Packet

Tags:Sprinkler k-factor orifice size

Sprinkler k-factor orifice size

VK532 - EC/QREC Upright Sprinkler (K11.2) Viking Group Inc.

WebK factor: 80 (5.6) Standard Orifice Size: 15mm (½”) Standard Thread Size: ½” NPT: Response: Standard Response: Bulb: 5mm: Maximum Working Pressure: 12.1 bar (175 … WebViking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK500 is a fast response fusible element type sprinkler designed for early fire suppression. With a 14.0 (202 …

Sprinkler k-factor orifice size

Did you know?

WebModel F4FR Concealed Sprinklers, 2.8, 4.2 & 5.6 K-Factor Model G1 Concealed Sprinklers, 3/8″, 7/16″, & 1/2″ Orifice Sizes Model G4XLO QREC Concealed Sprinklers Commercial Extended Coverage Distribution Patterns: Model G6-80 Concealed QR EC Horizontal Sidewall Sprinkler, 17/32” Orifice Model JL112 & J112 ECOH/ECLH – Pendent WebOrifice Size (mm) 16 16 16 16 Nominal K Factor Imperial 11.2 11.2 11.2 11.2 ... K-Factor Thread Size Sprinkler Finish Quantity Wrench Model Number RATINGS All glass bulbs are rated for temperatures from –67°F (–55°C) to those …

WebThe orifice size and SIN are stamped on the wrench boss. Thread size: 1/2” (15 mm) for VK790-VK794, 3/4” (20 mm) NPT for VK795 and VK796 Nominal K-Factors: Refer to the … WebThis online k factor calculator is able to find the flow, pressure or k factor from a sprinkler head or a water mist nozzle be using the K factor formula. This is the starting point for most water-based fire protection design and calculations. We can use this formula for any device for which we have a k factor and that can be a sprinkler, nozzle, water cannon, foam …

WebReFire Sydney +61 2 9879 0933 [email protected]. ReFire Newcastle +61 2 4961 1519 [email protected]. ReFire Brisbane +61 7 3208 9995 WebBecause sprinkler orifices are typically tapered, the orifice size is characterized by its discharge coefficient(k), which is used in the following formula to determine the discharge from a sprinkler: Q = k*P½, where Qis the discharge flow (gpm or L/min .), is the discharge coefficient of the sprinkler k (gal ./min . psi½or L/min . bar) and Pis …

Webdrop size distribution parameter gamma, and volume weighted velocity as a function of elevation and azimuthal angle. Table 1. Sprinkler k-factor and test pressures. Sprinkler A Sprinkler B Sprinkler C k-Factor 115 𝑃 / 0.5 (8 𝑃 /𝑝 𝑖0.5) 242 𝑃 / 0.5 𝑝 𝑖0.5) 363 𝑃 / 0.5

WebGL5610 is typically the sprinkler of choice when utilizing Residential Sprinklers within an NFPA 13 Occupancy. The larger K-factor can be advantageous when needed to con-form to the NFPA 13 hydraulic Special Design Approach for Residential Sprinklers. OPERATION Upon exposure to heat such as from a fire, the fluid in the kids birthday party rancho cucamongaWebResidential Sprinkler with a K-factor of 3.9, a temperature rating of 160°F/71°C, and a maximum working pressure of 175 psi. It qualifies for ... model, style, orifice size, temperature rating, type of finish, escutcheon plate finish and sprinkler wrench. For special painted escutcheon finishes, the customer must provide quick-drying or ... kids birthday party rentalsWebThis Tyco ESFR-17 Brass Upright Early Suppression Fast Response Fire Sprinkler features a fusible link activating at 165F (74C) with a 16.8 K-Factor, and 3/4 in. NPT threads. Each upright head features a brass frame and copper deflector. The manufacturer part number is 58-447-1-165 and the Sprinkler Identification Number (SIN) is TY7126. kids birthday party return giftsWeb18 Oct 2007 · The k-Factor is simply a constant. It is related to the size of the orifice in the sprinkler. I assume it was derived from empirical data. If you are familiar with the ideal gas law, PV=nRT. R is simply the gas constant that was derived from empirical data. Residual pressure is simply the pressure remaining in the piping system while water is ... kids birthday party rental placesWebThe addition of a larger K-Factor allows ESFR performance at lower end-head pressures than ESFR K14 sprinklers. K25.2 ESFR sprinklers can: -Eliminate the use of in-rack … kids birthday party rental ideashttp://www.internationalfog.com/documents/Automatic_Sprinkler_Basics.pdf is michael lockwood britishWeb7 Dec 2013 · 23.4.4.8.3 Sprinklers with different K-factors shall be acceptable for special use such as exposure protection, small rooms or enclosures, or directional discharge. (See 3.3.21 for definition of small rooms.) 23.4.4.8.4 Extended-coverage and residential sprinklers with a different K-factor shall be acceptable for part of the protection area ... is michael loftus married